LABNOVATION LD-100 POCT HbA1c Analyser Boronate Affinity Portable For HbA1c

Labnovation Technologies, Inc.
Contact Now

LABNOVATION LD-100 POCT HbA1c Analyser Boronate Affinity Portable For HbA1c

  • 1
  • 2

Brand Name : LABNOVATION

Model Number : LD-100

Certification : IFCC, NGSP, CE

Place of Origin : Shenzhen, China

MOQ : 1

Price : Negotiation

Payment Terms : D/A, D/P, T/T

Supply Ability : 100/Day

Delivery Time : 15-20 working days

Packaging Details : Carton

Name : Automated POCT HbA1c Analyzer For Glycated Hemoglobin Test

Sample types : Whole blood

Sample Volume : 4μL

Weight : 800g

Contact Now

HbA1c Analyzer LD-100 POCT HbA1c Analyzer Boronate Affinity Portable Analyzer For HbA1c

Intended Use

LLD-100 POCT Analyzer is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood which is a semi-automatic instrument used to analyze glycated hemoglobin. LD-100 is small and light, it can be used to detect of HbA1c in medical units at all levels. Fually Automatic system can help the test half work with double results.

Feature

  • Protable, easy to carry
  • Fast test speed, WIthin 3 minutes
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • Color touch screen
  • External printer (Blue-tooth)
  • USB Port, LIS Support

LABNOVATION LD-100 POCT HbA1c Analyser Boronate Affinity Portable For HbA1c

Specification

Model LD-100 Analyzer
Method Bornate Affinity
Measurement Time ≤3 min
Sample Type Whole blood
Shelf-Life of test kit 9 Months
Weight 800gs

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

Operation

1. Place cartridge in analyzer.

2. Push bead into reagents.

3. Insert sample into cartridge.

Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English; Abnormal alarm function.

Certificate

LABNOVATION LD-100 POCT HbA1c Analyser Boronate Affinity Portable For HbA1cLABNOVATION LD-100 POCT HbA1c Analyser Boronate Affinity Portable For HbA1c


Product Tags:

LD-100 Portable POCT HbA1c Analyzer

      

LABNOVATION POCT HbA1c Analyser

      

Boronate Affinity portable hba1c analyzer

      